THE ERROR CAUSED BY THE SIDE DECLINING ANGLE OF THE COUNTER SCANNING PLANE AND ITS EFFECT TO THE X-RAY STRESS MEASUREMENT |
Li Jiabao Institute of Metal Research; Academia Sinica |
|
Cite this article:
Li Jiabao Institute of Metal Research; Academia Sinica. THE ERROR CAUSED BY THE SIDE DECLINING ANGLE OF THE COUNTER SCANNING PLANE AND ITS EFFECT TO THE X-RAY STRESS MEASUREMENT. Acta Metall Sin, 1979, 15(3): 421-432.
|
Abstract The error in the X-ray stress measurement caused by the side declining angle, γ,of the counter scanning plane is shown to be: Δσ_X=-(σ_Ysin~2γ+τ_(XY)csin2ψ_i)in which D_i=∑sin~2ψ_i-nsin~2ψ/(∑sin~2ψ_i)~2-n∑sin~4ψ_i; n is the number of ψ. Such a relation isbeing supported by experimental results obtained in our laboratory. The error in stress measurements along axial direction of a cylindrical surfaceand certain problems encountered in the X-ray stress measurements of anomalous-ly shaped machine parts are discussed based on the above formula.
|
Received: 18 March 1979
|
[1] 金属研究所疲劳研究组,金属学报,13(1977) ,1. [2] 史连友,待发表工作. [3] 種村孝,材料试验,11(1962) ,631. [4] 日本材料学会,X線応力测定法,養贤堂,1966,p.180. [5] 小岛公平,材料试验,11(1962) ,637. [6] 金属研究所疲劳研究组,侧倾法X射线应力测定技术--原理、特点及应用,金属研究所资料,1978. |
No Suggested Reading articles found! |
|
|