Please wait a minute...
Acta Metall Sin  1979, Vol. 15 Issue (3): 421-432    DOI:
Current Issue | Archive | Adv Search |
THE ERROR CAUSED BY THE SIDE DECLINING ANGLE OF THE COUNTER SCANNING PLANE AND ITS EFFECT TO THE X-RAY STRESS MEASUREMENT
Li Jiabao Institute of Metal Research; Academia Sinica
Cite this article: 

Li Jiabao Institute of Metal Research; Academia Sinica. THE ERROR CAUSED BY THE SIDE DECLINING ANGLE OF THE COUNTER SCANNING PLANE AND ITS EFFECT TO THE X-RAY STRESS MEASUREMENT. Acta Metall Sin, 1979, 15(3): 421-432.

Download:  PDF(793KB) 
Export:  BibTeX | EndNote (RIS)      
Abstract  The error in the X-ray stress measurement caused by the side declining angle, γ,of the counter scanning plane is shown to be: Δσ_X=-(σ_Ysin~2γ+τ_(XY)csin2ψ_i)in which D_i=∑sin~2ψ_i-nsin~2ψ/(∑sin~2ψ_i)~2-n∑sin~4ψ_i; n is the number of ψ. Such a relation isbeing supported by experimental results obtained in our laboratory. The error in stress measurements along axial direction of a cylindrical surfaceand certain problems encountered in the X-ray stress measurements of anomalous-ly shaped machine parts are discussed based on the above formula.
Received:  18 March 1979     
Service
E-mail this article
Add to citation manager
E-mail Alert
RSS
Articles by authors

URL: 

https://www.ams.org.cn/EN/     OR     https://www.ams.org.cn/EN/Y1979/V15/I3/421

[1] 金属研究所疲劳研究组,金属学报,13(1977) ,1.
[2] 史连友,待发表工作.
[3] 種村孝,材料试验,11(1962) ,631.
[4] 日本材料学会,X線応力测定法,養贤堂,1966,p.180.
[5] 小岛公平,材料试验,11(1962) ,637.
[6] 金属研究所疲劳研究组,侧倾法X射线应力测定技术--原理、特点及应用,金属研究所资料,1978.
No related articles found!