Orginal Article

Corrosion Resistance of Ti-Fe Binary Alloys Fabricated by Powder Metallurgy

  • Wei XU ,
  • Xin LU ,
  • Yanxia DU ,
  • Qingyu MENG ,
  • Ming LI ,
  • Xuanhui QU
Expand
  • 1 Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China
    2 School of Metallurgical and Ecological Engineering, University of Science and Technology Beijing, Beijing 100083, China

Received date: 2016-04-07

  Online published: 2016-11-15

Supported by

Supported by Beijing Natural Science Foundation (No.2163053) and State Key Lab of Advanced Metals and Materials, USTB (No.2012Z-10)

Abstract

Titanium and its alloys have been widely used in the biomedical field, and have a great potential in making orthopedic implants due to their high specific strength, low elastic modulus, excellent biocompatibility and corrosion resistance in the human body environment. However, important titanium alloys currently used including extra low interstitial (ELI) Ti-6Al-4V (hereafter all in mass fraction, %), Ti-5Al-2.5Fe and Ti-6Al-7Nb are all at risk of releasing toxic Al and V ions in vivo. In addition, the elastic modulus (about 110 GPa) of these alloys are still much higher than those of cortical bones (about 20 GPa), which may bring severe ‘stress shielding’ for implantation failures. In order to solve these problems, much effort has been made to develop Al- and V-free lower-modulus β-Ti alloys. Considering that Fe is one of most effective and low-cost β-phase stabilizing element in titanium, binary Ti-Fe alloys have been selected and an assessment of the potential for biomedical applications has been conducted from the perspectives of their manufacturability, mechanical properties and biocorrosion performance. In this study, Ti-xFe (2%≤x≤20%) alloys were fabricated by powder metallurgy, and their microstructure and compression properties were characterized. In particular, the corrosion properties in four different simulated physiological electrolytes at (37±0.5) ℃ were investigated according to ASTM 59-97, compared with the performances of two commonly used titanium-based materials Ti-6Al-4V and commercially pure (CP) titanium. The results show that the content of β phase gradually increases with Fe content increasing. When Fe content goes up to 20%, the alloy samples are only composed of single β-phase grains. The PM-fabricated Ti-(2~20)Fe alloy is provided with a superior combination of mechanical properties, with the compressive strength range of 2096.2~2702.3 MPa, the compression ratio of 20.6%~33.2% and the elasticity modulus of 62.7~85.5 GPa. Higher Fe content tends to lead to the higher strength and ductility, but lower elastic modulus. In comparison, Ti-15Fe sintered at 1150 ℃ exhibits the superior mechanical properties, including the elastic modulus of 64.6 GPa, the compressive strength of 2702 MPa, and the compression rate of 32.7%. With the rise of Fe content in 2%~15%, the corrosion potential of alloys moves to a positive position, and the corrosion current density decreases, corresponding to the increase in the polarization resistance, which suggests the improvement of their corrosion properties. The binary alloy with 20%Fe possesses the similar corrosion performance to that of Ti-15Fe. The corrosion rates of Ti-15Fe alloy in simulated oral solution (FAS), phosphate buffer solution (PBS), simulated body fluid solution (SBF) and 0.9%NaCl solution (SS) are 1.7×10-3, 7.1×10-4, 1.2×10-3 and 3.5×10-4 mm/y, respectively. Compared with CP Ti and Ti-6Al-4V, Ti-15Fe alloy exhibits a more positive corrosion potential, smaller corrosion current density and higher polarization resistance, indicating a superior corrosion resistance.

Cite this article

Wei XU , Xin LU , Yanxia DU , Qingyu MENG , Ming LI , Xuanhui QU . Corrosion Resistance of Ti-Fe Binary Alloys Fabricated by Powder Metallurgy[J]. Acta Metall Sin, 2017 , 53(1) : 38 -46 . DOI: 10.11900/0412.1961.2016.00123

References

[1] Li Y Y, Zou L M, Yang C.Fabrication of biomedical Titanium alloys with high strength and low modulus by means of powder metallurgy[J]. J. South China Univ. Technol.: Nat. Sci. Ed., 2012, 40(10): 43
[1] (李元元, 邹黎明, 杨超. 粉末冶金法合成高强低模超细晶医用钛合金[J]. 华南理工大学学报(自然科学版), 2012, 40(10): 43)
[2] Zhao X F, Niinomi M, Nakai M, et al.Beta type Ti-Mo alloys with changeable Young's modulus for spinal fixation applications[J]. Acta Biomater., 2012, 8: 1990
[3] Mohammadi S, Wictorin L, Ericsonetal L E, et al.Cast titanium as implant material[J]. J. Mater. Sci.: Mater. Med., 1995, 6: 435
[4] Wang K.The use of titanium for medical applications in the USA[J]. Mater. Sci. Eng., 1996, A213: 134
[5] Niinomi M, Kuroda D, Fukunaga K, et al.Corrosion wear fracture of new β type biomedical titanium alloys[J]. Mater. Sci. Eng., 1999, A263: 193
[6] Chen B Y, Hwang K S, Ng K L.Effect of cooling process on the α phase formation and mechanical properties of sintered Ti-Fe alloys[J]. Mater. Sci. Eng., 2011, A528: 4556
[7] Jin Q, Li Q, Wang X Y.Study of Ti-Fe alloy preparation with powder metallurgy method[J]. J. Liaoning Inst. Technol.: Nat. Sci. Ed., 2015, 35(2): 120
[7] (金秋, 李强, 王新宇. 粉末冶金法制备Ti-Fe系合金的研究[J]. 辽宁工业大学学报(自然科学版), 2015, 35(2): 120)
[8] Meng Q Y, Lu X, Xu W, et al.Microstructure and mechanical properties of powder metallurgy Ti-Fe alloys[J]. Trans. Mater. Heat Treat., 2016, 37(8): 36
[8] (孟庆宇, 路新, 徐伟等. 粉末冶金Ti-Fe合金的显微组织及力学性能[J]. 材料热处理学报, 2016, 37(8): 36)
[9] Dewidar M M, Khalil K A, Lim J K.Processing and mechanical properties of porous 316L stainless steel for biomedical applications[J]. Trans. Nonferrous Met. Soc. China, 2007, 17: 468
[10] Yu H, Wegehaupt F J, Wiegand A, et al.Erosion and abrasion of tooth-colored restorative materials and human enamel[J]. J. Dent., 2009, 37: 913
[11] Liu Y, Chen L F, Tang H P, et al.Design of powder metallurgy titanium alloys and composites[J]. Mater. Sci. Eng., 2006, A418: 25
[12] Wang M, Song X P.Study actuality of corrosion, mechanical compatibility and biocompatibility of Titanium alloys for medical application[J]. Titanium Ind. Prog., 2008, 25(2): 13
[12] (王明, 宋西平. 医用钛合金腐蚀、力学相容性和生物相容性研究现状[J]. 钛工业发展, 2008, 25(2): 13)
[13] Majima K, Hirata T, Yamamoto M, et al.Tensile properties and corrosion behavior of hot isostatically pressed Ti-Fe alloy[J]. Nippon Kinzoku Gakkai-si, 1998, 52: 1113
[14] Solar R J, Pollack S R, Korostoff E.Titanium release from implants: a proposed mechanism [A]. Corrosion and Degradation of Implant Materials[C]. Philadelphia, PA: ASTM, 1979: 161
[15] Arcella F G, Froes F H.Producing titanium aerospace components from powder using laser forming[J]. JOM, 2000, 52(5): 28
[16] Lee E B, Han M K, Kim B J, et al.Effect of molybdenum on the microstructure, mechanical properties and corrosion behavior of Ti alloys[J]. Int. J. Mater. Res., 2014, 105: 847
[17] Wang B L, Zheng Y F, Zhao L C.Effects of Hf content and immersion timeon electrochemical behavior of biomedical Ti-22Nb-xHf alloys in 0.9%NaCl solution[J]. Mater. Corros., 2009, 60: 330
[18] Liu Y, Chen L F, Tang H P, et al.Design of powder metallurgy titanium alloys and composites[J]. Mater. Sci. Eng., 2006, A418: 25
[19] Zhang X P, Yu S R, He Z M, et al.Mechanical properties of new type Ti-Fe-Mo-Mn-Nb-Zr titanium alloy[J]. Chin. J. Nonferrous Met., 2002, 12(S1): 78
[19] (张新平, 于思荣, 何镇明等. 新型Ti-Fe-Mo-Mn-Nb-Zr系钛合金的力学性能[J]. 中国有色金属学报, 2002, 12(S1): 78)
[20] Bolat G, Mareci D, Chelariu R, et al.Investigation of the electrochemical behaviour of TiMo alloys in simulated physiological solutions[J]. Electrochim. Acta, 2013, 113: 470
[21] Hoar T P, Mears D C.Corrosion-resistant alloys in chloride solutions: materials for surgical implants[J]. Proc. Roy. Soc., 1966, 294A: 486
[22] Stern M, Geary A L.Electrochemical polarization I. A theoretical analysis of the shape of polarization curves[J]. J. Electrochem. Soc., 1957, 104: 56
[23] Majumdar P, Singh S B, Chakraborty M.The role of heat treatment on microstructure and mechanical properties of Ti-13Zr-13Nb alloy for biomedical load bearing applications[J]. J. Mech. Behav. Biomed. Mater., 2011, 4: 1132
[24] Bai Y, Hao Y L, Li S J, et al.Corrosion behavior of biomedical Ti-24Nb-4Zr-8Sn alloy in different simulated body solutions[J]. Mater. Sci. Eng., 2013, C33: 2159
[25] Mohan L, Anandan C.Wear and corrosion behavior of oxygen implanted biomedical titanium alloy Ti-13Nb-13Zr[J]. Appl. Surf. Sci., 2013, 282: 281
[26] Narayanan R, Seshadri S K.Point defect model and corrosion of anodic oxide coatings on Ti-6Al-4V[J]. Corros. Sci., 2008, 50: 1521
[27] Lu J W, Zhao Y Q, Niu H Z, et al.Electrochemical corrosion behavior and elasticity properties of Ti-6Al-xFe alloys for biomedical applications[J]. Mater. Sci. Eng., 2016, C62: 36
[28] Metikos-Hukovi? M, Kwokal A, Piljac J.The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution[J]. Biomaterials, 2003, 24: 3765