Inconel 690TT和Incoloy 800MA蒸汽发生器管材在高温高压水中的腐蚀行为研究*

  • 王俭秋 ,
  • 黄发 ,
  • 柯伟
展开
  • 中国科学院金属研究所中国科学院核用材料与安全评价重点实验室, 沈阳 110016

收稿日期: 2016-07-01

  网络出版日期: 2016-08-02

基金资助

* 国家杰出青年基金资助项目51025104

CORROSION BEHAVIORS OF INCONEL 690TT AND INCOLOY 800MA STEAM GENERATOR TUBES IN HIGH TEMPERATURE HIGH PRESSURE WATER

  • Jianqiu WANG ,
  • Fa HUANG ,
  • Wei KE
Expand
  • Key Laboratory of Nuclear Materials and Safety Assessment, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China

Received date: 2016-07-01

  Online published: 2016-08-02

Supported by

Supported by National Funds for Distinguished Young Scholars (No.51025104)

摘要

利用多种分析手段深入分析了Inconel 690TT和Incoloy 800MA合金蒸汽发生器管材及其在高温高压水环境中的腐蚀行为. 结果表明, 沿管材厚度方向从内壁至外壁, Inconel 690TT合金管材Σ3晶界偏离理想晶界的程度逐渐增大, Kernel平均取向差(KAM)也逐渐增大, 管材外壁为最薄弱区; Incoloy 800MA合金管材Σ3晶界偏离理想晶界的程度均匀, 且主要集中于0~1°的小偏差范围内, KAM应变的变化也趋于平缓. 溶氧的高温纯H2O中, Inconel 690TT合金表面腐蚀产物为双层膜结构, 外层为富Fe尖晶石与NiO小颗粒, 内层膜为NiO相且疏松多孔, 不能对基体起到良好的保护作用, 局部区域腐蚀深度可达716 nm; Incoloy 800MA合金表面腐蚀产物为双层膜结构, 外层为大颗粒状尖晶石相, 内层膜为小颗粒尖晶石相, Cr在内层膜与基体的界面富集, 平均腐蚀深度仅约为150 nm. 相同条件下, 溶氧的高温纯H2O中Incoloy 800MA合金的内层膜厚度显著小于Inconel 690TT合金. 因此, 在溶氧高温高压纯H2O环境中, Cr发生溶解, Incoloy 800MA合金比Inconel 690TT合金耐蚀性更优.

本文引用格式

王俭秋 , 黄发 , 柯伟 . Inconel 690TT和Incoloy 800MA蒸汽发生器管材在高温高压水中的腐蚀行为研究*[J]. 金属学报, 2016 , 52(10) : 1333 -1344 . DOI: 10.11900/0412.1961.2016.00276

Abstract

Inconel 690TT and Incoloy 800MA have been widely used as steam generator heat transfer tubes in nuclear power plants (NPPs). The corrosion behaviors of these two alloys in high temperature high pressure water have to be fully addressed. This work systematically studied the microstructures of the as-received Inconel 690TT and Incoloy 800MA steam generator tubes (SGTs) and compared the oxide films formed on the tubing materials in high temperature water using several analytical methods including SEM, EBSD, GIXRD, SAED and STEM. The results show that from outer surface to inner surface of Inconel 690TT SGTs, the deviation degrees from the ideal Σ3 misorientation and the average value of Kernel average misorientation (KAM) gradually increase. The outer surface of Inconel 690TT SGTs are weakest. For Incoloy 800MA SGTs, the deviation degrees from the ideal Σ3 misorientation are within 0~1°, and the change of KAM average value is small. Exposed to 325 ℃ pure water containing 0.75×10-6 O2 for 720 h, oxide films of both Inconel 690TT SGTs and Incoloy 800MA SGTs have duplex structure. On Inconel 690TT SGTs, the outer layer is Fe-rich spinel and small NiO particles; the inner layer mainly is NiO, porous and less protective with the thickness of 716 nm. On Incoloy 800MA SGTs, the outer layer is big polyhedral spinel; the inner layer is small polyhedral spinel and protective with the average thickness of 150 nm; Cr is enriched at the interface between inner oxide layer and matrix. In high temperature water with dissolved oxygen, due to the preferential dissolution of Cr, Incoloy 800MA is more corrosion resistant than Inconel 690TT.

参考文献

[1] Dutta R S, Tewari R, De P K.Corros Sci, 2007; 49: 303
[2] Lee K H, Cragnolino G, MacDonald D D.Corrosion, 1985; 41: 540
[3] Cels J R.Corrosion, 1978; 34: 198
[4] Gadiyar H S.In: Symposium on Current Trends in Water Chemistry of Nuclear and Thermal Power Plants and Other Related Units (CURTWAC-95), Bombay, India, 1995: 9
[5] Pathania R S, Cleland R D.Corrosion, 1985; 41: 575
[6] Chen C M, Aral K.EPRI NP-3137, 1983; 2: 5
[7] Xiao J M.Corrosion Theory—Material Corrosion and its Control Methods. Beijing: Chemical Industry Press, 1994: 1
[7] (肖纪美. 腐蚀总论——材料的腐蚀及其控制方法. 北京: 化学工业出版社, 1994: 1)
[8] Copson H R, Cheng C F.Corrosion, 1957; 13: 397
[9] Ledjeff K, Rahmel A, Schorr M.Werkst Korros, 1979; 30: 767
[10] Angeliu T, Was G.J Electroch Soc, 1993; 140: 1877
[11] Carrette F, Lafont M, Chatainier G, Guinard L, Pieraggi B.Surf Interface Anal, 2002; 34: 135
[12] MacHet A, Galtayries A, Marcus P, Combrade P, Jolivet P, Scott P.Surf Interface Anal, 2002; 34: 197
[13] Ziemniak S E, Hanson M.Corros Sci, 2003; 45: 1595
[14] Ziemniak S E, Hanson M.Corros Sci, 2006; 48: 498
[15] Sennour M, Marchetti L, Martin F, Perrin S, Molins R, Pijolat M.J Nucl Mater, 2010; 402: 147
[16] Scott P M, Combrade P.ASM Handbook. Vol.13C, Materials Park, OH: ASM International, 2006: 362
[17] Li X H, Huang F, Wang J Q, Han E-H, Ke W.Acta Metall Sin, 2011; 47: 847
[17] (郦晓慧, 黄发, 王俭秋, 韩恩厚, 柯伟. 金属学报, 2011; 47: 847)
[18] Shimada M, Kokawa H, Wang Z, Sato Y, Karibe I.Acta Mater, 2002; 50: 2331
[19] Gertsman V, Bruemmer S M.Acta Mater, 2001; 49: 1589
[20] Peng Q, Shoji T, Yamauchi H, Takeda Y.Corros Sci, 2007; 49: 2767
[21] Crawford D C, Was G S.Metall Trans, 1992; 23A: 1195
[22] Gertsman V Y, Tangri K, Valiev R.Acta Metall Mater, 1994; 42: 1785
[23] Pan Y, Adams B, Olson T, Panayotou N.Acta Mater, 1996; 44: 4685
[24] Lemire R, McRae G.J Nucl Mater, 2001; 294: 141
[25] Kim Y, Andresen P.Corrosion, 2003; 59: 584
[26] Kuang W, Wu X, Han E-H, Rao J.Corros Sci, 2011; 53: 3853
[27] Tan L, Rakotojaona L, Allen T R, Nanstad R K, Busby J T.Mater Sci Eng, 2011; A528: 2755
[28] Rothman S J, Nowicki L J, Murch G E.J Phys, 1980; 10F: 383
[29] Kim Y J.Corrosion, 2000; 56: 389
[30] Robertson J.Corros Sci, 1991; 32: 443
[31] Terachi T, Arioka K.Corrosion 2006, San Diego, March 12-16, paper No.06608
[32] Staehle R W, Gorman J A.Corrosion, 2003; 59: 931
[33] Wang J Q, Li X H, Huang F, Zhang Z M, Wang J Z, Staehle R W.Corrosion, 2014; 70: 598
文章导航

/