DL-EPR法评价2205双相不锈钢晶间腐蚀敏感性
收稿日期: 2009-09-09
修回日期: 2009-12-17
网络出版日期: 2010-03-11
基金资助
国家自然科学基金项目50871031和50701010, 上海市科委专项基金项目09ZR1402600和09JC1401600与上海市重点学科项目B113资助
EVALUATION OF THE SUSCEPTIBILITY TO INTERGRANULAR ATTACK OF 2205 DUPLEX STAINLESS STEEL BY DL-EPR METHOD
Received date: 2009-09-09
Revised date: 2009-12-17
Online published: 2010-03-11
Supported by
Supported by National Natural Science Foundation of China (Nos.50871031 and 50701010), Shanghai Science and Technology Development Funds (Nos.09ZR1402600 and 09JC1401600) and Shanghai Leading Academic Discipline Project (No.B113)
徐菊良 . DL-EPR法评价2205双相不锈钢晶间腐蚀敏感性[J]. 金属学报, 2010 , 46(3) : 380 -384 . DOI: 10.3724/SP.J.1037.2009.00598
Duplex stainless steels (DSS), consisted of ferrite and austenite, are widely used in oil, chemical, petrochemical, nuclear and marine industries because of their attractive combination of higher mechanical strength and corrosion resistance in various aggressive environments. However, precipitations of detrimental phases, such as chromium carbides, nitrides, intermetallic phases (χ, σ) inevitably occur when manufacturing conditions and welding procedure heat these duplex stainless steels to temperature ranging from 300 to 1000 ℃, which results in a reduction in corrosion properties due to the presence of chromium-depleted zones around these precipitates. In this paper, the microstructure evolution of 2205 DSS was studied qualitatively at 800 ℃ by using Thermo-Calc coupled with optical microscope. The double-loop electrochemical potentiokinetic reactivation (DL-EPR) was optimized through studying the influences caused by four factors (scan rate, temperature, the concentration of the electrolyte and the surface finish). Then the susceptibility to intergranular attack (IGA) of 2205 DSS was tested by optimized DL-EPR. The results indicated that σ phase will be precipitated in the ferrite phase when 2205 DSS aged at 800 ℃, and the volume fraction would increase with the aging time increasing. The optimized DL-EPR test can evaluate the susceptibility to IGA of 2205 DSS both quantitatively and qualitatively, which is proved by the morphologies of the sample after D--EPR test.
Key words: 2205 duplex stainless steel; DL-EPR; susceptibility to IGA; σ phase
[1] Gao W, Luo J M, Yang J J. Ord Mater Sci Eng, 2005; 28: 61
(高娃, 罗建民, 杨建君. 兵器材料科学与工程, 2005; 28: 61)
[2] Nilsson J O. Mater Sci Technol, 1992; 8: 685
[3] Lopez N, Cid M, Puiggali M. Corros Sci, 1999; 41: 1615
[4] Wilms M E, Gadgil V J, Krougmen J M, Ijsseling F P. Corros Sci, 1994; 36: 871
[5] Strauss B, Schottky H, Hennuber J. Anor Allgem Chem, 1930; 188: 309
[6] Huey W R. Trans Am Soc Steel Treating, 1930; 18: 1126
[7] Streicher M A. Corros Sci, 1969; 9: 53
[8] Cihal V, Desestret A, Froment M, Wagner G H. ´ Etude de Nouveaux Tests Potentiocin´etiques de Corrosion Intergranulaire des Aciers Inoxydables. ´Etude CETIM–Center de Recherches de Firminy, C.A.F.L., 1969: 958
[9] Clarke W L, Romero V M, Danko J C. Corrosion, 1977; 77: 130
[10] Umemura F, Kawamoto T, Gijutsu B. Corr Eng Jpn, 1979; 28: 24
[11] Jin W S, Lang Y P, Rong F, Sun L J. J Chin Soc Corros Prot, 2007; 27: 54
(金维松, 郎宇平, 荣凡, 孙力军. 中国腐蚀与防护学报, 2007; 27: 54)
[12] Scully J R, Kelly R G. Corrosion, 1986; 42: 537
[13] Duret-Thual D, Bonis M, Crolet J L. Mater Corros, 2001; 52: 37
[14] Amadou T, Braham C, Sidhom H. Metall Mater Trans, 2004; 35A: 3499
[15] Garc´?a C, Mart´?n F, Blanco Y, de Tiedra M P, Aparicio M L. Corros Sci, 2009; 51: 76
[16] Deng B, Jiang Y M, Xu J L, Sun T, Gao J,Zhang L H, Zhang W, Li J. Corros Sci, 2009, doi:
10.1016/j.corsci.2009.11.020
[17] Li S S. Corros Sci Technol Prot, 2000; 12: 288
(李神速. 腐蚀科学与防护技术, 2000; 12: 288)
[18] Lee K M, Cho H S, Choi D C. J Alloys Compd, 1999; 285: 156
[19] Majidi A P, Streicher M A. Corrosion, 1984; 40: 393
[20] Sahlaoui H, Makhlouf K, Sidhom H, Philibert J. Mater Sci Eng, 2004; A372: 98
/
| 〈 |
|
〉 |