5A06合金TIG焊接头敏化失效机制及还原调控
李维, 冯杰涛, 房灿峰, 冯肖, 高武, 刘敏, 王英敏

Sensitization Failure Mechanism and Reversion Regulation of TIG Welded Joints in 5A06 Alloy
LI Wei, FENG Jietao, FANG Canfeng, FENG Xiao, GAO Wu, LIU Min, WANG Yingmin
图9 5A06合金焊接态、敏化及还原样品不同区域经NAMLT测试后截面形貌的OM像
Fig.9 Cross-sectional OM images showing the intergranular corrosion propagation paths after NAMLT for as-welded (a, d, g, j); 175 oC, 100 h sensitized (b, e, h, k); 310 oC, 1 h short-term reversion treated (c, f, i); and 310 oC, 24 h long-term reversion treated (l) 5A06 alloy samples (Figs.9j and k show the enlarged images of Figs.9g and h, respectively) (a-c) BM (d-f) HAZ (g-l) WZ