表2 灭菌NS4溶液中的EIS拟合结果
Table 2 Fitting results of EIS in sterile NS4 solution
SteelTime / dRs / (Ω·cm2)QdlRct / (Ω·cm2)χ2
Ydl / (S·s n ·cm-2)ndl
NS-1#1193.61.387 × 10-40.83651.733 × 1046.07 × 10-4
2188.87.166 × 10-50.89531.881 × 1058.79 × 10-4
4175.85.981 × 10-50.90824.377 × 1057.93 × 10-4
7169.25.488 × 10-50.91105.946 × 1058.95 × 10-4
14141.95.519 × 10-50.91046.011 × 1059.05 × 10-4
NS-2#1198.81.427 × 10-40.83856.071 × 1048.29 × 10-4
2196.15.011 × 10-50.89159.385 × 1041.05 × 10-3
4183.63.830 × 10-50.93853.809 × 1059.87 × 10-3
7171.43.783 × 10-40.94255.215 × 1051.01 × 10-3
14148.44.342 × 10-30.94784.932 × 1059.08 × 10-4
NS-3#1193.48.350 × 10-50.84611.814 × 1046.85 × 10-4
2190.14.959 × 10-50.91821.428 × 1051.15 × 10-3
4179.44.756 × 10-50.93691.956 × 1059.09 × 10-4
7166.55.263 × 10-50.94132.121 × 1055.82 × 10-4
14143.97.236 × 10-50.94431.481 × 1056.28 × 10-4