蛋白质吸附对医用金属材料体外腐蚀行为的影响
王鲁宁, 刘丽君, 岩雨, 杨坤, 陆黎立

Influences of Protein Adsorption on the in vitro Corrosion of Biomedical Metals
WANG Luning, LIU Lijun, YAN Yu, YANG Kun, LU Lili
表1 Mg及镁合金体内外测试中的腐蚀速率[3~7] (mm/a, unless otherwise indicated)
Table 1 The in vitro and in vivo corrosion rates of Mg and Mg alloys[3-7]
MaterialIn vitroIn vivoRef.
SolutionWeight lossHydrogen evolutionVolume reductions/
weight loss
Pure MgPBS0.28±0.070.19±0.020.15±0.03[3]
HBSS0.72±0.310.57±0.07
DMEM1.07±0.100.57±0.07
Mg-10GdPBS0.61±0.100.40±0.101.11±0.05[3]
HBSS1.57±0.621.23±0.56
DMEM0.42±0.120.20±0.01
Mg-2AgPBS16.71±3.0615.12±2.970.13±0.04[3]
HBSS5.41±0.713.48±0.36
DMEM2.21±0.260.68±0.04
Pure MgDMEM

Static immersion 1.6±0.3

Aortic bioreactor:

Lumen>4.0±0.8

Wall 1.9±0.5

Aortic lumen 1.1±0.3[4]
Aortic wall 1.5±0.6
Mg-2SrHBSS~0.37~0.321.37[5]
Mg-2Sr-CaHBSS~0.24~0.211.10[5]
Mg-2Sr-ZnHBSS~0.15~0.110.85[5]
Pure MgHBSS17.2%±0.5% (14 d)65.4%±1.5% (4 weeks)[6]
Mg+Ca-Sr-P coatingHBSS4.8%±0.7% (14 d)76.7%±1.9% (4 weeks)[6]
Mg-30%Sc (mass fraction)HBSSα+β phase 3.4±0.1β phase 0.06±0.01[7]
Single phase 2.9±0.1