焊接线能量对5182-O/HC260YD+Z异种材料CMT搭接接头组织与性能的影响
吉华,邓运来,徐红勇,郭伟强,邓建峰,范世通

The Influence of Welding Line Energy on the Microstructure and Property of CMT Overlap Joint of 5182-Oand HC260YD+Z
Hua JI,Yunlai DENG,Hongyong XU,Weiqiang GUO,Jianfeng DENG,Shitong FAN
表2 图4各点EDS分析结果
Table 2 EDS of the points in Fig.4
PointAtomic fraction / %Possible phase
AlFeMgSiOthers (C, O et al)
A24.0852.78-0.9922.15γ-Fe+FeAl
B37.4522.10-1.7138.74FeAl2
C53.9915.520.171.8828.44FeAl3
E34.9431.98-2.1430.94FeAl